{"id":17532,"date":"2026-09-29T01:27:31","date_gmt":"2026-09-29T01:27:31","guid":{"rendered":"https:\/\/drakemarine.com\/?post_type=product&#038;p=17532"},"modified":"2026-09-30T01:34:29","modified_gmt":"2026-09-30T01:34:29","slug":"fullriver-hgxl200-2-2v-200ah-stationary-agm-battery","status":"publish","type":"product","link":"https:\/\/drakeoffgrid.com\/ru\/product\/fullriver-hgxl200-2-2v-200ah-stationary-agm-battery\/","title":{"rendered":"Fullriver HGXL200-2 \u2014 2V 200Ah Stationary AGM Battery"},"content":{"rendered":"<p>The Fullriver HGXL200-2 is a 2-volt, 200 Ah (10-hour rate) stationary AGM cell from Fullriver&#8217;s long-life HGXL series. It is a single-cell design: you build exactly the bank you need \u2014 12, 24 or 48 V, or a higher string for telecom and UPS \u2014 from identical cells, and if a cell ever needs attention you test or replace that one cell rather than a whole battery. The grids are cast in a lead-calcium-tin alloy for corrosion resistance, which is what gives the series its 20-year design life in float service. Sealed, valve-regulated and maintenance-free, with no free acid to top up or spill, so cells can be racked in any orientation.<\/p>\n<h3>\u0413\u0434\u0435 \u044d\u0442\u043e \u0443\u043c\u0435\u0441\u0442\u043d\u043e<\/h3>\n<p>The core of the range for off-grid and hybrid solar storage on houses, resorts and island properties, marina and yacht-club shore installations, and standby power for pumps, gates, communications and security systems. Sized on the 10-hour rate, a bank of these cycles gently every night and is built to keep doing so for years.<\/p>\n<h3>Why a 2 V cell rather than a 12 V block<\/h3>\n<p>Long-life solar and standby banks are built from 2 V cells for good reasons. Capacity per cell runs far beyond anything a 12 V case can hold, so a big bank is one clean string instead of a web of parallel blocks. Every cell can be measured, equalised and replaced on its own. And HGXL cells are rated at the 10-hour rate \u2014 the honest rate for solar and standby duty \u2014 with the 1-, 3- and 5-hour figures published too, so you can size for heavier loads without guesswork.<\/p>\n<h3>Specifications \u2014 HGXL200-2<\/h3>\n<table>\n<tr>\n<td><strong>\u041d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u0435 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435<\/strong><\/td>\n<td>2 V<\/td>\n<\/tr>\n<tr>\n<td><strong>Capacity @ 10 hr rate (C10)<\/strong><\/td>\n<td>200 Ah<\/td>\n<\/tr>\n<tr>\n<td><strong>\u0412\u043c\u0435\u0441\u0442\u0438\u043c\u043e\u0441\u0442\u044c \u043f\u043e 5-\u0447\u0430\u0441\u043e\u0432\u043e\u043c\u0443 \u0442\u0430\u0440\u0438\u0444\u0443<\/strong><\/td>\n<td>170 Ah<\/td>\n<\/tr>\n<tr>\n<td><strong>Capacity @ 3 hr rate<\/strong><\/td>\n<td>150 Ah<\/td>\n<\/tr>\n<tr>\n<td><strong>Capacity @ 1 hr rate<\/strong><\/td>\n<td>110 \u0410\u0447<\/td>\n<\/tr>\n<tr>\n<td><strong>Dimensions (L \u00d7 W \u00d7 H, case)<\/strong><\/td>\n<td>172 \u00d7 110 \u00d7 330 mm<\/td>\n<\/tr>\n<tr>\n<td><strong>Total height incl. terminals<\/strong><\/td>\n<td>365 mm<\/td>\n<\/tr>\n<tr>\n<td><strong>Weight (approx.)<\/strong><\/td>\n<td>16 \u043a\u0433<\/td>\n<\/tr>\n<tr>\n<td><strong>Terminal<\/strong><\/td>\n<td>\u041c8<\/td>\n<\/tr>\n<tr>\n<td><strong>Internal resistance (fully charged)<\/strong><\/td>\n<td>0.51 m\u03a9<\/td>\n<\/tr>\n<tr>\n<td><strong>Maximum charge current<\/strong><\/td>\n<td>20 % of C10 (40 A)<\/td>\n<\/tr>\n<tr>\n<td><strong>Float charge voltage<\/strong><\/td>\n<td>2.23 \u2013 2.25 V per cell (20 \u2013 25 \u00b0C)<\/td>\n<\/tr>\n<tr>\n<td><strong>Cycle charge voltage<\/strong><\/td>\n<td>2.30 \u2013 2.35 V per cell (20 \u2013 25 \u00b0C)<\/td>\n<\/tr>\n<tr>\n<td><strong>\u0422\u0435\u043c\u043f\u0435\u0440\u0430\u0442\u0443\u0440\u043d\u0430\u044f \u043a\u043e\u043c\u043f\u0435\u043d\u0441\u0430\u0446\u0438\u044f<\/strong><\/td>\n<td>\u22123 mV per \u00b0C per cell<\/td>\n<\/tr>\n<tr>\n<td><strong>Grid alloy<\/strong><\/td>\n<td>Lead \u2013 calcium \u2013 tin (Pb-Ca-Sn)<\/td>\n<\/tr>\n<tr>\n<td><strong>Plates \/ separator<\/strong><\/td>\n<td>Flat pasted plates, absorbent glass mat<\/td>\n<\/tr>\n<tr>\n<td><strong>\u0421\u043b\u0443\u0447\u0430\u0439<\/strong><\/td>\n<td>ABS, flame-retardant (UL94-HB)<\/td>\n<\/tr>\n<tr>\n<td><strong>\u0414\u0438\u0437\u0430\u0439\u043d\u0435\u0440\u0441\u043a\u0430\u044f \u0436\u0438\u0437\u043d\u044c<\/strong><\/td>\n<td>20 years in float service at 25 \u00b0C (Fullriver&#8217;s published figure)<\/td>\n<\/tr>\n<\/table>\n<h3>Building a bank<\/h3>\n<p>Six cells in series give 12 V, twelve give 24 V and twenty-four give 48 V; the bank&#8217;s capacity is the cell&#8217;s rating. Twenty-four HGXL200-2 cells make a 48 V, 200 Ah bank \u2014 9.6 kWh at the 10-hour rate \u2014 in a single string. Tell us the voltage, the daily load and the space you have and we will size the string, the rack, the inter-cell links and the charging with it.<\/p>\n<h3>\u0417\u0430\u0440\u044f\u0434\u043a\u0430<\/h3>\n<p>Float at 2.23 \u2013 2.25 V per cell and cycle-charge at 2.30 \u2013 2.35 V per cell (20 \u2013 25 \u00b0C), with charge current limited to 20 % of C10 \u2014 40 A for this cell. Always charge with temperature compensation (\u22123 mV per \u00b0C per cell): in tropical heat that one setting protects a bank more than anything else you can fit. We pair HGXL banks with <a href=\"https:\/\/drakemarine.com\/product-category\/electrical\/battery-chargers\/\" target=\"_blank\" rel=\"noopener\">KISAE multi-stage chargers<\/a> \u0438 <a href=\"https:\/\/drakemarine.com\/product-category\/electrical\/inverter-chargers\/\" target=\"_blank\" rel=\"noopener\">inverter-chargers<\/a> fitted with a <a href=\"https:\/\/drakemarine.com\/product\/kisae-battery-temperature-sensor-bts-10k\/\" target=\"_blank\" rel=\"noopener\">battery temperature sensor<\/a>, so the whole system is specified together.<\/p>\n<h3>\u0420\u0443\u043a\u043e\u0432\u043e\u0434\u0441\u0442\u0432\u0430<\/h3>\n<ul>\n<li><a href=\"https:\/\/drakemarine.com\/2v-stationary-batteries\/\" target=\"_blank\" rel=\"noopener\">2 V stationary batteries: range, sizing calculator and applications<\/a><\/li>\n<li><a href=\"https:\/\/drakemarine.com\/48v-battery-bank-2v-cells\/\" target=\"_blank\" rel=\"noopener\">Building a 48 V bank from 2 V cells<\/a><\/li>\n<li><a href=\"https:\/\/drakemarine.com\/2v-agm-charging-float-voltage\/\" target=\"_blank\" rel=\"noopener\">Charging 2 V AGM cells: float, cycle and temperature compensation<\/a><\/li>\n<li><a href=\"https:\/\/drakemarine.com\/telecom-ups-2v-battery-string\/\" target=\"_blank\" rel=\"noopener\">Telecom, UPS and switchgear strings<\/a><\/li>\n<li><a href=\"https:\/\/drakemarine.com\/agm-vs-opzv-opzs-gel-lithium\/\" target=\"_blank\" rel=\"noopener\">AGM vs OPzV, OPzS, gel and lithium<\/a><\/li>\n<\/ul>\n<h3>\u0414\u043e\u0441\u0442\u0430\u0432\u043a\u0430<\/h3>\n<p>HGXL cells are supplied to order from Fullriver and we confirm the lead time with your quote. Sealed non-spillable AGM travels as ordinary cargo by road and sea. Delivery in Thailand by courier or pallet freight, with our own free delivery run covering Trang, Krabi and Phuket; worldwide freight is quoted at cost and invoiced separately, never marked up.<\/p>\n<h3>\u0417\u0430\u0433\u0440\u0443\u0437\u043a\u0438<\/h3>\n<ul class=\"dm-downloads\">\n<li><a href=\"https:\/\/www.fullriver.com\/upload\/article\/20260314\/69b4be411bcc9.pdf\" target=\"_blank\" rel=\"noopener\">Fullriver HGXL200-2 datasheet (PDF)<\/a><\/li>\n<li><a href=\"https:\/\/www.fullriver.com\/batteries\/agm-batteries\/stationary-lead-acid-batteries.html\" target=\"_blank\" rel=\"noopener\">Fullriver HGXL series overview<\/a><\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>2 V 200 Ah (C10) stationary AGM cell from Fullriver&#8217;s HGXL series. Pb-Ca-Sn grid, 20-year design life on float, sealed and maintenance-free. Build any bank voltage from identical cells. Supplied to order.<\/p>","protected":false},"featured_media":17531,"template":"","meta":{"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"_kad_post_classname":""},"product_brand":[],"product_cat":[34],"product_tag":[],"dm_channel":[1940],"class_list":["post-17532","product","type-product","status-publish","has-post-thumbnail","product_cat-batteries","first","instock","taxable","shipping-taxable","purchasable","product-type-simple","entry","content-bg","loop-entry"],"_links":{"self":[{"href":"https:\/\/drakeoffgrid.com\/ru\/wp-json\/wp\/v2\/product\/17532","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/drakeoffgrid.com\/ru\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/drakeoffgrid.com\/ru\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/drakeoffgrid.com\/ru\/wp-json\/wp\/v2\/media\/17531"}],"wp:attachment":[{"href":"https:\/\/drakeoffgrid.com\/ru\/wp-json\/wp\/v2\/media?parent=17532"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/drakeoffgrid.com\/ru\/wp-json\/wp\/v2\/product_brand?post=17532"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/drakeoffgrid.com\/ru\/wp-json\/wp\/v2\/product_cat?post=17532"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/drakeoffgrid.com\/ru\/wp-json\/wp\/v2\/product_tag?post=17532"},{"taxonomy":"dm_channel","embeddable":true,"href":"https:\/\/drakeoffgrid.com\/ru\/wp-json\/wp\/v2\/dm_channel?post=17532"}],"curies":[{"name":"WP","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}